124 resultados para sensitivity and specificity

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: The purpose of our study was to retrospectively evaluate the specificity, sensitivity and accuracy of computed tomography (CT), digital radiography (DR) and low-dose linear slit digital radiography (LSDR, Lodox(®)) in the detection of internal cocaine containers. METHODS: Institutional review board approval was obtained. The study collectively consisted of 83 patients (76 males, 7 females, 16-45 years) suspected of having incorporated cocaine drug containers. All underwent radiological imaging; a total of 135 exams were performed: nCT=35, nDR=70, nLSDR=30. An overall calculation of all "drug mules" and a specific evaluation of body packers, pushers and stuffers were performed. The gold standard was stool examination in a dedicated holding cell equipped with a drug toilet. RESULTS: There were 54 drug mules identified in this study. CT of all drug carriers showed the highest diagnostic accuracy 97.1%, sensitivity 100% and specificity 94.1%. DR in all cases was 71.4% accurate, 58.3% sensitive and 85.3% specific. LSDR of all patients with internal cocaine was 60% accurate, 57.9% sensitive and 63.4% specific. CONCLUSIONS: CT was the most accurate test studied. Therefore, the detection of internal cocaine drug packs should be performed by CT, rather than by conventional X-ray, in order to apply the most sensitive exam in the medico-legal investigation of suspected drug carriers. Nevertheless, the higher radiation applied by CT than by DR or LSDR needs to be considered. Future studies should include evaluation of low dose CT protocols in order to address germane issues and to reduce dosage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To retrospectively assess the diagnostic sensitivity of 45° Dunn view and cross-table lateral radiographs for the assessment of cam deformity by comparison with radial MRI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Meta-analysis of predictive values is usually discouraged because these values are directly affected by disease prevalence, but sensitivity and specificity sometimes show substantial heterogeneity as well. We propose a bivariate random-effects logitnormal model for the meta-analysis of the positive predictive value (PPV) and negative predictive value (NPV) of diagnostic tests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The German version of the Conners Adult ADHD Rating Scales (CAARS) has proven to show very high model fit in confirmative factor analyses with the established factors inattention/memory problems, hyperactivity/restlessness, impulsivity/emotional lability, and problems with self-concept in both large healthy control and ADHD patient samples. This study now presents data on the psychometric properties of the German CAARS-self-report (CAARS-S) and observer-report (CAARS-O) questionnaires.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fluorescence microlymphography (FML) is used to visualize the lymphatic capillaries. A maximum spread of the fluorescence dye of ≥ 12 mm has been suggested for the diagnosis of lymphedema. However, data on sensitivity and specificity are lacking. The aim of this study was to investigate the accuracy of FML for diagnosing lymphedema in patients with leg swelling. Patients with lower extremity swelling were clinically assessed and separated into lymphedema and non-lymphatic edema groups. FML was studied in all affected legs and the maximum spread of lymphatic capillaries was measured. Test accuracy and receiver operator characteristic (ROC) analysis was performed to assess possible threshold values that predict lymphedema. Between March 2008 and August 2011 a total of 171 patients (184 legs) with a median age of 43.5 (IQR 24, 54) years were assessed. Of those, 94 (51.1%) legs were diagnosed with lymphedema. The sensitivity, specificity, positive and negative likelihood ratio and positive and negative predictive value were 87%, 64%, 2.45, 0.20, 72% and 83% for the 12-mm cut-off level and 79%, 83%, 4.72, 0.26, 83% and 79% for the 14-mm cut-off level, respectively. The area under the ROC curve was 0.82 (95% CI: 0.76, 0.88). Sensitivity was higher in the secondary versus primary lymphedema (95.0% vs 74.3%, p = 0.045). No major adverse events were observed. In conclusion, FML is a simple and safe technique for detecting lymphedema in patients with leg swelling. A cut-off level of ≥ 14-mm maximum spread has a high sensitivity and high specificity of detecting lymphedema and should be chosen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the study was to determine the sensitivity and specificity for typical abdominal injuries after major blunt trauma in postmortem multislice computed tomography (MSCT) and magnetic resonance imaging (MRI).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Anecdotal evidence suggests that the sensitivity and specificity of a diagnostic test may vary with disease prevalence. Our objective was to investigate the associations between disease prevalence and test sensitivity and specificity using studies of diagnostic accuracy. METHODS We used data from 23 meta-analyses, each of which included 10-39 studies (416 total). The median prevalence per review ranged from 1% to 77%. We evaluated the effects of prevalence on sensitivity and specificity using a bivariate random-effects model for each meta-analysis, with prevalence as a covariate. We estimated the overall effect of prevalence by pooling the effects using the inverse variance method. RESULTS Within a given review, a change in prevalence from the lowest to highest value resulted in a corresponding change in sensitivity or specificity from 0 to 40 percentage points. This effect was statistically significant (p < 0.05) for either sensitivity or specificity in 8 meta-analyses (35%). Overall, specificity tended to be lower with higher disease prevalence; there was no such systematic effect for sensitivity. INTERPRETATION The sensitivity and specificity of a test often vary with disease prevalence; this effect is likely to be the result of mechanisms, such as patient spectrum, that affect prevalence, sensitivity and specificity. Because it may be difficult to identify such mechanisms, clinicians should use prevalence as a guide when selecting studies that most closely match their situation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

People with sequence-space synesthesia (SSS) report stable visuo-spatial forms corresponding to numbers, days, and months (amongst others). This type of synesthesia has intrigued scientists for over 130 years but the lack of an agreed upon tool for assessing it has held back research on this phenomenon. The present study builds on previous tests by measuring the consistency of spatial locations that is known to discriminate controls from synesthetes. We document, for the first time, the sensitivity and specificity of such a test and suggest a diagnostic cut-off point for discriminating between the groups based on the area bounded by different placement attempts with the same item.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The most commonly used method for formally assessing grapheme-colour synaesthesia (i.e., experiencing colours in response to letter and/or number stimuli) involves selecting colours from a large colour palette on several occasions and measuring consistency of the colours selected. However, the ability to diagnose synaesthesia using this method depends on several factors that have not been directly contrasted. These include the type of colour space used (e.g., RGB, HSV, CIELUV, CIELAB) and different measures of consistency (e.g., city block and Euclidean distance in colour space). This study aims to find the most reliable way of diagnosing grapheme-colour synaesthesia based on maximising sensitivity (i.e., ability of a test to identify true synaesthetes) and specificity (i.e., ability of a test to identify true non-synaesthetes). We show, applying ROC (Receiver Operating Characteristics) to binary classification of a large sample of self-declared synaesthetes and non-synaesthetes, that the consistency criterion (i.e., cut-off value) for diagnosing synaesthesia is considerably higher than the current standard in the field. We also show that methods based on perceptual CIELUV and CIELAB colour models (rather than RGB and HSV colour representations) and Euclidean distances offer an even greater sensitivity and specificity than most currently used measures. Together, these findings offer improved heuristics for the behavioural assessment of grapheme-colour synaesthesia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In colorectal cancer, tumor budding at the invasive front (peritumoral budding) is an established prognostic parameter and decreased in mismatch repair-deficient tumors. In contrast, the clinical relevance of tumor budding within the tumor center (intratumoral budding) is not yet known. The aim of the study was to determine the correlation of intratumoral budding with peritumoral budding and mismatch repair status and the prognostic impact of intratumoral budding using 2 independent patient cohorts. Following pancytokeratin staining of whole-tissue sections and multiple-punch tissue microarrays, 2 independent cohorts (group 1: n = 289; group 2: n = 222) with known mismatch repair status were investigated for intratumoral budding and peritumoral budding. In group 1, intratumoral budding was strongly correlated to peritumoral budding (r = 0.64; P < .001) and less frequent in mismatch repair-deficient versus mismatch repair-proficient cases (P = .177). Sensitivity and specificity for lymph node positivity were 72.7% and 72.1%. In mismatch repair-proficient cancers, high-grade intratumoral budding was associated with right-sided location (P = .024), advanced T stage (P = .001) and N stage pN (P < .001), vascular invasion (P = .041), infiltrating tumor margin (P = .003), and shorter survival time (P = .014). In mismatch repair-deficient cancers, high intratumoral budding was linked to higher tumor grade (P = .004), vascular invasion (P = .009), infiltrating tumor margin (P = .005), and more unfavorable survival time (P = .09). These associations were confirmed in group 2. High-grade intratumoral budding was a poor prognostic factor in univariate (P < .001) and multivariable analyses (P = .019) adjusting for T stage, N stage distant metastasis, and adjuvant therapy. These preliminary results on 511 patients show that intratumoral budding is an independent prognostic factor, supporting the future investigation of intratumoral budding in larger series of both preoperative and postoperative rectal and colon cancer specimens.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Foreign body ingestion is common and potentially lethal. This study evaluates the use of low-dose Statscans (LODOX) in emergency departments. DESIGN: This comparative cross-sectional study retrospectively assessed 28 289 digital chest x-rays and 2301 LODOX scans performed between 2006 and 2010 at a tertiary emergency centre. The radiographic appearance, image quality and location of ingested foreign bodies were evaluated in standard digital chest and LODOX radiography. The mean irradiation (μSv) and cumulative mean radiation dose per patient with the ingested foreign body were calculated according to literature-based data, together with the sensitivity and specificity for each modality. RESULTS: A total of 62 foreign bodies were detected in 39 patients, of whom 19 were investigated with LODOX and 20 with conventional digital chest radiography. Thirty-three foreign bodies were located in the two upper abdominal quadrants, 21 in the lower quadrants-which are not visible on conventional digital chest radiography-seven in the oesophagus and one in the bronchial system. The sensitivity and specificity of digital chest radiography were 44.4% and 94.1%, respectively, and for the LODOX Statscan 90% and 100%, respectively. The calculated mean radiation dose for LODOX investigations was 184 μS, compared with 524 μS for digital chest radiography. CONCLUSIONS: LODOX Statscan is superior to digital chest radiography in the diagnostic work-up of ingested foreign bodies because it makes it possible to enlarge the field of view to the entire body, has higher sensitivity and specificity, and reduces the radiation dose by 65%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neurodegenerative diseases affect the cerebellum of numerous dog breeds. Although subjective, magnetic resonance (MR) imaging has been used to detect cerebellar atrophy in these diseases, but there are few data available on the normal size range of the cerebellum relative to other brain regions. The purpose of this study was to determine whether the size of the cerebellum maintains a consistent ratio with other brain regions in different ages and breeds of normal dogs and to define a measurement that can be used to identify cerebellar atrophy on MR images. Images from 52 normal and 13 dogs with cerebellar degenerative diseases were obtained. Volume and mid-sagittal cross-sectional area of the forebrain, brainstem, and cerebellum were calculated for each normal dog and compared between different breeds and ages as absolute and relative values. The ratio of the cerebellum to total brain and of the brainstem to cerebellum mid-sagittal cross-sectional area was compared between normal and affected dogs and the sensitivity and specificity of these ratios at distinguishing normal from affected dogs was calculated. The percentage of the brain occupied by the cerebellum in diverse dog breeds between 1 and 5 years of age was not significantly different, and cerebellar size did not change with increasing age. Using a cut off of 89%, the ratio between the brainstem and cerebellum mid-sagittal cross-sectional area could be used successfully to differentiate affected from unaffected dogs with a sensitivity and specificity of 100%, making this ratio an effective tool for identifying cerebellar atrophy on MR images.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Falls of elderly people may cause permanent disability or death. Particularly susceptible are elderly patients in rehabilitation hospitals. We systematically reviewed the literature to identify falls prediction tools available for assessing elderly inpatients in rehabilitation hospitals. Methods and Findings We searched six electronic databases using comprehensive search strategies developed for each database. Estimates of sensitivity and specificity were plotted in ROC space graphs and pooled across studies. Our search identified three studies which assessed the prediction properties of falls prediction tools in a total of 754 elderly inpatients in rehabilitation hospitals. Only the STRATIFY tool was assessed in all three studies; the other identified tools (PJC-FRAT and DOWNTON) were assessed by a single study. For a STRATIFY cut-score of two, pooled sensitivity was 73% (95%CI 63 to 81%) and pooled specificity was 42% (95%CI 34 to 51%). An indirect comparison of the tools across studies indicated that the DOWNTON tool has the highest sensitivity (92%), while the PJC-FRAT offers the best balance between sensitivity and specificity (73% and 75%, respectively). All studies presented major methodological limitations. Conclusions We did not identify any tool which had an optimal balance between sensitivity and specificity, or which were clearly better than a simple clinical judgment of risk of falling. The limited number of identified studies with major methodological limitations impairs sound conclusions on the usefulness of falls risk prediction tools in geriatric rehabilitation hospitals.